Fix wrong remaining length calculation.

This commit is contained in:
Christian Kratky
2018-06-05 23:39:59 +02:00
parent 1d455221e4
commit 00ac9ce961
3 changed files with 13 additions and 18 deletions
@@ -93,11 +93,11 @@ namespace MQTTnet.Serializer
private static async Task<int> ReadBodyLengthAsync(IMqttChannel channel, byte initialEncodedByte, CancellationToken cancellationToken)
{
// Alorithm taken from https://docs.oasis-open.org/mqtt/mqtt/v3.1.1/errata01/os/mqtt-v3.1.1-errata01-os-complete.html.
var multiplier = 1;
var value = (byte)(initialEncodedByte & 127) * multiplier;
var multiplier = 128;
var value = initialEncodedByte & 127;
int encodedByte = initialEncodedByte;
var buffer = new byte[1];
while ((encodedByte & 128) != 0)
{
var readCount = await channel.ReadAsync(buffer, 0, 1, cancellationToken).ConfigureAwait(false);